Technical parameters:
Nominal pressure: 2.8MPa Applicable temperature:-50℃~+150℃
Test pressure: 4.2MPa Applicable medium:ammonia,fluorine,etc.
Characteristics:
- The Pilots ACVP-H are used as constant pressure regulators, mounted directly over
main valves AM1 or AM3 but can be also mounted on a housing valve CVH in a
external line to control one or more AM or RAK valves.
- The Pilots ACVP-H working in higher pressure with a range of 4 Bars to 25 Bars.
- Turning the regulating spindle clockwise to increase the opening pressure of the pilot,
(thus the condensating pressure and temperature),and they decrease when we turn the
spindle anticlockwise.
- ACVP-H pilot valve is used to keep AM main valve inlet pressure constant. It can
also be used as a safety valve. For example, to prevent excessive pressure due to the
presence of effusion.
- Must use stainless steel bolts when it is used at ambient temperature below-50C.
Technical parameters:
Nominal pressure: 2.8MPa Applicable temperature:-50℃~+150℃
Test pressure: 4.2MPa Applicable medium:ammonia,fluorine,etc.
Characteristics:
- The Pilots ACVP-H are used as constant pressure regulators, mounted directly over
main valves AM1 or AM3 but can be also mounted on a housing valve CVH in a
external line to control one or more AM or RAK valves.
- The Pilots ACVP-H working in higher pressure with a range of 4 Bars to 25 Bars.
- Turning the regulating spindle clockwise to increase the opening pressure of the pilot,
(thus the condensating pressure and temperature),and they decrease when we turn the
spindle anticlockwise.
- ACVP-H pilot valve is used to keep AM main valve inlet pressure constant. It can
also be used as a safety valve. For example, to prevent excessive pressure due to the
presence of effusion.
- Must use stainless steel bolts when it is used at ambient temperature below-50C.